ELECTRICAL SPECS - INVERTER |
AC Output Operating Voltage Options |
120, 110, 108 Vac |
Continuous Output Power |
Continuous Power 2000 W @40 C True sine wave (TSW) |
Continuous AC Output Current |
16.7 A |
Surge Power |
4000 W (? 5 sec) |
Frequency (Configurable) |
60 (or 50) Hz |
Peak Efficiency |
91% |
Full Load Efficiency |
gretaer than or equal to 86% |
DC Input Operating voltage range |
10.1 - 18.0 VDC |
DC Input Max Non-Operating Voltage |
25.2 Vdc |
DC Nominal Current at Full Load |
192 Adc |
ELECTRICAL SPECS - BATTERY CHARGER |
Min Battery Voltage for Charging |
0.0 Vdc |
Max DC Output Voltage |
18.0 Vdc (custom battery type) |
Selectable DC Output Current |
User Selectable: 5 - 100 A |
Full Load Max AC Input Current |
24 Arms |
Max DC Charge Current (selectable down to 5A) |
100A |
Operating Input AC Pass-Through Voltage Range |
85-140 Vac |
Safe Non-Operating Input AC Voltage Range |
Up to 240 Vac RMS |
Power Factor at Full Charge Rate |
> 98% |
GENERAL SPECS |
Operating Temperature Range |
4 to 140 F (-20 to 60 C), with output derated above 104 F (40 °C) |
Storage Temperature Range |
-40 to 158 F (-40 to 70 C) |
Operating Humidity Range |
5 to 95% RH, non-condensing |
Transfer Relay AC Current Rating |
30 A surge, 24 A continous |
DC Input/Output Nominal Voltage (inverting/ Charging) |
12.0 Vdc |
L x W x H (without flanges) |
15.4"(390 mm) x 10.8"(275 mm) x 4.9"(125 mm) |
L x W x H (with flanges) |
16.0"(406 mm) x 12.0"(305 mm) x 4.9"(125 mm) |