General specifications |
Output voltage |
100/110/115/120 V — 50/60 Hz (selectable) |
Output waveform |
true sine |
Nominal battery voltage |
24 V |
Recommended battery capacity |
≥ 50 Ah |
Continuous power at 25 °C / 77 °F, cos phi 1 |
700 W |
Continuous power at 40 °C / 104 °F, cos phi 1 |
700 W |
Peak load (1 min.) |
< 810 W |
Peak load (1 s) |
< 1230 W |
AC connection |
North American socket with GFCI |
Galvanic isolation |
Yes |
Efficiency |
93 % |
Display/read-out |
LED indication: battery voltage, load level, status |
Alarms |
potential free alarm contact |
Dimensions, hxwxd |
7.9 x 13.0 x 3.3 inch |
Weight |
5.7 lb |
Technical specifications |
Technology |
high frequency, input & output fully isolated |
Low battery voltage, switches off at |
21 V |
Low battery voltage, switches on at |
25 V |
High battery voltage, switches off at |
33 V |
High battery voltage, switches on at |
29 V |
Input current (nominal load) |
35 A |
No-load power consumption (ON mode) |
< 0.8 A |
No-load power consumption (energy saving mode) |
< 0.06 A |
Minimal DC fuse (slow blow) |
50 A |
Minimal cable size |
16 mm
|
Harmonic distortion typical |
< 5 % |
Cos phi |
all power factors allowed |
Temperature range (ambient temp.) |
-4 °F to 140 °F |
Cooling |
temperature and load controlled fan |
Protection degree |
IP21, horizontal wall mounting |
Protections |
over-temperature, overload, short circuit, high/low voltage, reverse polarity (fuse) |
MasterBus compatible |
yes, using a MasterBus AC Master Interface |