The XPLORE 120/12 battery charger is the largest and most powerful charger in the market today. The universal, auto-ranging AC input and 120 amps of output current ensures ultra-fast and reliable worldwide charging. With up to six output banks of simultaneous charging combined with the ability to charge two battery banks with differing chemistries, the XPLORE 120/12 eliminates the need to have separate single-chemistry chargers and minimizes installation and wiring costs for your house bank and engine bank.
It is also equipped with an easy-to-read front panel LED display for basic configuration and status information. Advanced monitoring and configuration is enabled by NMEA 2000 protocol or Xantrex app using the Xantrex BLE module.
ELECTRICAL SPECIFICATIONS |
Max Total BAT1-6 DC Output Current |
120A |
Max Total BAT1-2 DC Output |
Current 5 to 120A (selectable) |
Max Total BAT3-6 DC Output |
Current 5 to 40A (selectable) |
DC Output Voltage |
12Vdc (nominal) |
DC Output Connections |
6 |
AC Input Voltage (Auto Ranging) |
120Vac / 230Vac (nominal), 80 to 265 Vac |
Power Factor at Full Charge Rate |
> 98% |
Charging Modes |
3-Stage, 2-Stage, Constant Voltage |
Supported Battery Types |
AGM, FLD, GEL, Xantrex LFP, Custom |
Equalization (FLD Battery Only) |
Yes |
GENERAL SPECIFICATIONS |
Operating Temperature |
4 to 140 F (-20 to 60 C), with output derated above 122 F (50°C) |
Storage Temperature |
40 to 176 F (-40 to 80 C) |
Operating Humidity |
5 to 95% RH, non-condensing |
AC Input Terminal Connection |
3-position tool-free spring clamp terminal |
DC Output Terminal Connection |
BAT1-2: Two M6 stud terminals |
L x W x H Charger |
16.26in (413mm) x 12.34in (312mm) x 6.5in (165mm) |
Ingress Protection (IP) Rating Charger: |
IP-32 (vertical) |
REGULATORY APPROVALS |
Safety |
ETL listed to CSA C22.2 No. 107.2, conforms to UL Std. UL1236 (with Marine Supplement) |
EMC |
47 CFR (FCC) Part 15B, Class B and CAN ICES-3(B) / NMB-3(B) |
Ignition Protection |
SAE J1171, ABYC C-1500 |